Lumen Output 4,810 lm Power Consumption 27 W | 35 W | 46 W Typical Lifetime (TM21 Reported) > 60,000 hours @ 40°C Ambient (B10, L90, TM21 Reported) Typical Lifetime (TM21 Projected) 179,506 hours @ 40°C Ambient (B10, L90, TM21 Projected) Input Voltage International: 220-240 Vac, 50 Hz | North America: 120/277 Vac, 60 Hz Earth Leakage 0.2 mA @ 120 Vac, 0.42 mA @ 240 Vac, 0.24 mA @ 277 Vac Control Protocols DALI 2 (International), 0-10 V (North America), Non-Dimmable IP Rating IP66 / IP67 (Passes IP68 Test) IK Rating IK6 construction; IK10 accessories available on request Vibration Resistance 3G Rating (ANSI C136.31) Color Options Warm White Cool White Data Sheet

Specifications

Videos

Product Highlights | Linealux L3 Foundation
A brief introduction of the DALI lighting controls used in the Linealux L3 solution by Lumascape.
Webinar | Foundation Family
Watch the webinar introducing Lumascape's Foundation range of enhanced lighting controls

Product Configurator

Length

Select the luminaire length

Customise Linealux L3 Foundation below

Power Consumption

For all non-dimming or DALI controlled luminaires

Required

12 W/ft (12D)

Light Source

Required

Static White (827)

Static White (827)

2,700 K (80 CRI, 3 SDCM)

Static White (830)

Static White (830)

3,000K (80 CRI, 3 SDCM)

Static White (835)

Static White (835)

3,500K (80 CRI, 3 SDCM)

Static White (840)

Static White (840)

4,000 K (80 CRI, 3 SDCM)

Static White (750)

Static White (750)

5,000K (70 CRI, 3 SDCM)

Connection Type

Required

Connectorized for loop in/out (73)

Connectorized for loop in/out (73)

For connection to the branch circuit via LS6402 Leader cable. Supports loop in/out.

Connectorized for single connection point (77)

Connectorized for single connection point (77)

For connection to the branch circuit via LS6402 Leader cable. Loop in/out not supported.

Beam Angles

Published angles may vary slightly to photometric data. Please refer to IES files where relevant.

Required

Very Narrow (VN)

Very Narrow (VN)

Narrow (NR)

Narrow (NR)

10°

Narrow Medium (NM)

Narrow Medium (NM)

15°

Medium (ME)

Medium (ME)

30°

Wide (WD)

Wide (WD)

45°

Wide Flood (WF)

Wide Flood (WF)

60°

Narrow Horizontal (NH)

Narrow Horizontal (NH)

10º x 40º

Linear Horizontal (LH)

Linear Horizontal (LH)

10º x 60º

Medium Horizontal (MH)

Medium Horizontal (MH)

20º x 40º

Wide Horizontal (WH)

Wide Horizontal (WH)

20º x 60º

Direct Flood (FL)

Direct Flood (FL)

100º

Asymmetric Left (AL)

Asymmetric Left (AL)

Asymmetric Right (AR)

Asymmetric Right (AR)

Mounting

Required

Adjustable Bracket (A)

Adjustable Bracket (A)

Fixed Bracket (B)

Fixed Bracket (B)

Input Voltage

Required

120/277 Vac, 60 Hz (09)

120/277 Vac, 60 Hz (09)

Line Voltage

Control

Required

Non-Dimmable (ND)

For single color, non-dimming applications only.

0-10 V (AH)

For single color dimming applications via 0-10 V.

Finish

Custom powder coat colours are available. Please consult factory.

Required

Black (BL)

Black (BL)

RAL9004 from RAL Classic collection (formerly CB)

More info
Anthracite Gray (AG)

Anthracite Gray (AG)

RAL7016 from RAL Classic collection

More info
Basalt Gray (BT)

Basalt Gray (BT)

RAL7012 from RAL Classic collection

More info
Graphite Gray (GH)

Graphite Gray (GH)

Graphite Gray

More info
Anodic Silver (SL)

Anodic Silver (SL)

RAL9006 from RAL Classic collection (formerly CS)

More info
White (WT)

White (WT)

RAL9016 from RAL Classic collection

More info
Dark Bronze (DB)

Dark Bronze (DB)

RAL8019 from RAL Classic collection

More info
Latte (LT)

Latte (LT)

RAL7006 from RAL Classic collection

More info
Dark Aluminium (DA)

Dark Aluminium (DA)

RAL9007 from RAL Classic collection

More info
Custom RAL (CC)

Custom RAL (CC)

A one-off custom color setup fee applies. Click on 'More Info' button to add to your enquiry. Contact Lumascape for volume discount on set-up fee.

More info

Luminaire Gap

Required

End-To-End (000)

Luminaire is configured for end-to-end spacing - no jumper cables needed

1 ft / 0.3 m Gap (001)

Configured for 1 ft (305 mm) spacing - no jumper cables needed

2 ft / 0.6 m Gap (002)

Configured for 2 ft (610 mm) spacing - no jumper cables needed

3 ft / 0.9 m Gap (003)

Configured for 3 ft / 915 mm) spacing - no jumper cables needed

6 ft / 1.8 m Gap (006)

Configured for 6 ft (1,800 mm) spacing - no jumper cables needed

Accessories